Commissioning, Testing and Start-Up of Electrical Systems
Start Date | End Date | Venue | Fees (US $) | ||
---|---|---|---|---|---|
Commissioning, Testing and Start-Up of Electrical Systems | 14 Dec 2025 | 18 Dec 2025 | Live-Online | $ 2,500 | Register |

Commissioning, Testing and Start-Up of Electrical Systems
Start Date | End Date | Venue | Fees (US $) | |
---|---|---|---|---|
Commissioning, Testing and Start-Up of Electrical Systems | 14 Dec 2025 | 18 Dec 2025 | Live-Online | $ 2,500 |
Introduction
The successful operation of Electrical Systems ultimately depends on how well the Testing, Start-Up and Commissioning is carried out on each system. Well-developed procedures will in the long run result in reduced 1) costs, 2) start-up delays, 3) parts requirements and 4) troubleshooting time.Delegates are encouraged to raise queries both during and at any time after attending the course. Delegates are also encouraged to bring with them any issues or experiences that they may have to this course.Following the attendance at this course, participants will return to their respective organizations equipped with new skills and knowledge to enable them to more effectively start-up and commission electrical systems and to solve problems that arise during these activities.This in turn will reduce down time, improve equipment availability and reliability and allow the transfer of these skills to the participants co-workers.
Objectives
- To develop a better understanding of various test equipment used in electrical testing.
- To develop a better understanding of various electrical equipment and control systems design, functionality, and failure modes.
- To better understand work practices, which allow for a successful start-up, commissioning, and troubleshooting including job plans.
- To provide examples of successful techniques and ‘hands-on experiences plus case studies and group problem-solving exercises
To develop a structured approach to electrical systems using common terminology and to provide methods and solutions for various electrical systems start-up and commissioning.
Training Methodology
This is an interactive course. There will be open question and answer sessions, regular group exercises and activities, videos, case studies, and presentations on best practice. Participants will have the opportunity to share with the facilitator and other participants on what works well and not so well for them, as well as work on issues from their own organizations. The online course is conducted online using MS-Teams/ClickMeeting.
On successful completion of this course, participants will have:
-
A better understanding of start-up and commissioning procedures
-
An improved capability in the use of test equipment
-
An understanding of the importance of logical and timely attendance to electrical problems through the use of troubleshooting procedures
-
A better understanding of failure modes and failure analysis
-
Improved awareness of the safety concerns associated with electrical apparatus
Who Should Attend?
This course is intended for Electrical Maintenance Engineers, Supervisors and Technicians working in a start-up, commissioning or testing related roles that need either a greater awareness of, or to become more proficient in, the aspects of electrical systems and electrical maintenance activities. Because the methods and examples are generic, personnel from all industries will benefit.
Course Outline
Day 1: Definitions/Procedures
- Testing, Start-Up, Commissioning and Troubleshooting
- Electrical Systems: AC (High Voltage, Medium Voltage, Low Voltage)
- DC
- Emergency Power and/or Cogeneration Power
- HVAC
- Lighting
- Fire Detection, Alarm and Suppression
- Safety, Security and Surveillance
Industrial Electrical Symbols
- Circuit Interrupter, Disconnect, Circuit Breaker
- Overload, Contacts
- Switch
- Transformer
- Meter
- Motor
- Electrical Components and Logic Symbols
Drawings
- Single Line HV (Switchgear)
- Single Line MV (Switchgear)
- Single Line LV (MCC)
- Single Line Wiring Schedule
- Single Line MV (Distribution)
- Protective Device Schematic
Test Equipment
- Digital Volt Meter with Temperature and Frequency accessories
- Oscilloscope/ScopeMeter
- Megger
- Ohm Meter
Day 2: AC Electrical System – High Voltage (7.5kV to 750kV)
Input Power from Local Utility Company
Power Transformer
- Bushings
- Mechanical Protection Devices and Indicators
- Electrical Protection Devices and Indicators
- Cooling Fans and Radiators
- Configuration
- Electrical Bus and Wiring Connections
- Current and Potential Transformers
Switch Gear
- Bus and Wiring Connections
- Knife Edges/Disconnects
- Insulators
- Fusing/Circuit Breaker/Tie Breaker
- Feeder Protection Relays
- Current and Potential Transformers
AC Electrical System – Medium Voltage (750V to 7.5kV)
Transformer
- Bushings
- Mechanical Protection Devices and Indicators
- Electrical Protection Devices and Indicators
- Cooling Fans and Radiators
- Configuration
- Electrical Bus and Wiring Connections
- Current and Potential Transformers
Switch Gear
- Bus and Wiring Connections
- Knife Edges/Disconnects/Contactors
- Insulators
- Control Metering/Indicators
- Fusing/Circuit Breaker/Tie Breaker
- Feeder Protection Relays
- Current and Potential Transformers
Motors
- Motor Protection Relays
- Vibration Analysis
- Hand-Off-Auto Functions
- Wiring Connections
AC Electrical System – Low Voltage (up to 750V)
Transformer
- Bushings
- Mechanical Protection Devices and Indicators
- Electrical Protection Devices and Indicators
- Radiators
- Configuration
- Electrical Bus and Wiring Connections
- Current and Potential Transformers
Motor Control Centre (MCC)
- Bus and Wiring Connections
- Fusing/Circuit Breaker
- Feeder Protection Relays
- Current and Potential Transformers
- Control Metering/Indicators
- Control Transformers
- Contactors
- Overloads
- Lighting Contactors
- Variable Frequency Drives (VFD)
Motors
- Motor Protection Relays
- Vibration Analysis
- Hand-Off-Auto Functions
- Wiring Connections
Miscellaneous Loads
- Heaters
- Pumps
- Wall Outlets
- Distribution Panel Boxes
- Distribution Transformers
- Solenoid Valves
- Electric Valve Actuators
Day 3: DC Electrical System
Transformer
- Bushings
- Mechanical Protection Devices and Indicators
- Electrical Protection Devices and Indicators
- Radiators
- Configuration
- Electrical Bus and Wiring Connections
- Current and Potential Transformers
AC Motor Control Centre (MCC)
- Bus and Wiring Connections
- Fusing/Circuit Breaker
- Feeder Protection Relays
- Current and Potential Transformers
- Control Metering/Indicators
- Control Transformers
- Contactors
- Overloads
DC Motor Control Centre (MCC)
- Rectifier
- Bus and Wiring Connections
- Fusing/Circuit Breaker
- Wiring Connections
- Variable Speed Drives (VSD)
- Rectifier
- Control Metering/Indicators
Motors
- Motor Protection Relays
- Vibration Analysis
- Hand-Off-Auto Functions
- Wiring Connections
Miscellaneous Loads
- Heaters
- Solenoid Valves
- Electric Valve Actuators
Emergency Power and/or Cogeneration Power
Generation
Generator
- Wiring Connections
- Driver and Fuel Source
Transformer
- Bushings
- Mechanical Protection Devices and Indicators
- Electrical Protection Devices and Indicators
- Radiators
- Configuration
- Electrical Bus and Wiring Connections
- Current and Potential Transformers
Motor Control Centre (MCC)
- Bus and Wiring Connections
- Fusing/Circuit Breaker
- Feeder Protection Relays
- Current and Potential Transformers
- Control Metering/Indicators
- Control Transformers
- Contactors
- Overloads
- Lighting Contactors
- Static Synchronizing Switch
Motors
- Motor Protection Relays
- Hand-Off-Auto Functions
- Wiring Connections
Miscellaneous Loads
- Heaters
- Pumps
- Wall Outlets
- Distribution Panel Boxes
- Distribution Transformers
- Solenoid Valves
- Electric Valve Actuators
Day 4: AC Uninterruptible Power Supply (UPS)
Rectifier
- Wiring Connections
- Circuit Breakers/Fusing
- Control Metering/Indicators
Batteries
- Wiring Connections
- Battery Fluids/Specific Gravity
Inverter
- Wiring Connections
- Circuit Breakers/Fusing
- Control Metering/Indicators
Static Switch
- Wiring Connections
Loads
- Wiring Connections
- UPS Wall Outlets
- Computer Controlled Equipment
DC Uninterruptible Power Supply (UPS)
Rectifier
- Wiring Connections
- Circuit Breakers/Fusing
- Control Metering/Indicators
Batteries
- Wiring Connections
- Battery Fluids/Specific Gravity
Loads
- Wiring Connections
- Specialized Wall Outlets
- ESD Valve Actuators
- Critical Switchgear Motorized Actuators
Heating, Ventilating And Air Conditioning (HVAC)
Power
- Wiring Connections
- Circuit Breakers/Fusing
Furnaces
- Fuel Supply
- Wiring Connections
- Temperature Control
Fans
- Wiring Connections
- Temperature/Air Flow Control
Air Conditioning
- Temperature Control
- Wiring Connections
- Compressor/Coolant Unit
Lighting
Lighting Transformers
- Configuration
- Wiring Connections
- Cooling
Lighting Panels
- Wiring Connections
- Circuit Breakers
Lighting
- Wiring Connections
- Harmonics
- Lighting Ballasts
- Lighting Fixtures
- Lighting Dimmers
Day 5: Fire Detection, Alarm and Suppression
Detection
- Sensors
- Wiring Connections
- Control Equipment
Alarm
- Audible
- Visual
- Wiring Connections
- Relays
Suppression
- Water Deluge
- CO2
- Wiring Connections
- Solenoids
Safety, Security and Surveillance
Toxic Gas
- Detectors
- Wiring Connections
- Control Equipment
- Alarms/Indicators
Explosive Gas
- Detectors
- Wiring Connections
- Control Equipment
- Alarms/Indicators
Entry Control
- Door/Window Switches
- Wiring Connections
Closed Circuit TV (CCTV)
- Cameras/Recorders
- Wiring Connections
- Control Equipment
- Alarms/Indicators
Regulatory Considerations
- Area Classifications
- Electrical Safety
- Electrical Codes